Measurement length up to 3,000 mm
Protection class IP56
Optional magnetic absolute encoder
Optional redundant version
Output | Potentiometer 1 kΩ Voltage 0... 10 V, 0.5 … 10 V Current 4 ... 20 mA, 2 or 3 wire Voltage or current output, programmable (PMUV/PMUI) Voltage or current output, redundant SSI CANopen CANopen redundant SAE J1939 SAE J1939 redundant Incremental encoder |
Resolution | Analog: <0.002 % f.s. ADSI16/MSSI16: max. 16 bit f.s. |
Linearity | Up to ±0.05 % f.s. |
Sensing device | Precision potentiometer Optical encoder Magnetic absolute encoder |
Housing material | Aluminum Measuring cable: stainless steel |
Protection class | IP67 |
Connection | Connector M12 |
Weight | up to 1,500 mm approx. 1 kg, from 2,000 mm approx. 1.5 kg |